ZYPCOM SE-Series: Zypcom's Corporate Class Modem![]() Zypcom Z34-SE, Z32t-SE, Z32b-SE features:
Zypcom's SE-Series ( Z34-SE, Z32t-SE, Z32b-SE ) of modems are designed for data communication applications that go beyond PC connectivity. The feature-rich SE-Series modems are proven leaders in data throughput—even on impaired telephone lines. Network World said "the best overall performer" of high-speed modems. Data Communications bestowed their "Top Performer" award. Byte said "sends and receives data faster than any modem." Zypcom's Z34-SE modem incorporates V.34 technology for line speeds up to 33.6Kbps. The Z32t-SE modem incorporates V.32terbo technology for 19.2Kbps line speeds. The Z32b-SE modem incorporates V.32bis technology for 14.4Kbps line speeds. More Than 4x Faster A powerful datapump, in conjunction with enhanced V.42bis data compression, makes this modem more than four times faster than regular modems using the equivalent modulation. The Zypcom Z34-SE offers the highest modem speeds available for faster file transfers and greater productivity. One Modem, Lower Costs with Zypcom Z34-SE, Z32t-SE, Z32b-SE Each SE-Series modem is a versatile network modem that provides data communication professionals with application flexibility. It is ideal for asynchronous desktop communications, remote LAN and Windows NTTM applications and IBM® synchronous communications. The SE-Series family of modems is compatible with the PC's AT autodialing commands or the AS/400's V.25bis commands. Sophisticated remote diagnostics and modem control, combined with an optional PC-based network management system and features too numerous to mention, deliver unmatched performance, reliability, and functionality. On the Z34-SE, future controller and DSP enhancements are added quickly with the flash memory design. Price/Performance - Zypcom Z34-SE, Z32t-SE, Z32b-SE With its ease-of-use, compatibility, security options, manageability, versatility and the highest full-duplex data throughput of any modem today, the SE-Series offers the data communications professional the best price/performance ratio available. Network World said "Zypcom provides the biggest bang for the buck." Specifications of Zypcom Z34-SE, Z32t-SE, Z32b-SEZypcom SE-Series Modem Family Compatibility Z34-SE: V.34+, V.34, V.32ter, V.32bis, V.32, V.22bis, V.23, V.22, V.21, 212A, 103 Z32t-SE: V.32ter, V.32bis, V.32, V.22bis, V.23, V.22, V.21, 212A, 103 Z32b-SE: V.32bis, V.32, V.22bis, V.23, V.22, V.21, 212A, 103 Automode: V.34+, V.34, V.32ter, V.32bis, V.32, V.22bis, V.22, V.23, V.21, 212A, 103 Operating Speeds DTE rates (asynchronous): 230.4K (Z34-SE only), 115.2K, 57.6K, 38.4K, 19.2K, 9600, 4800, 2400, 1200 and 300 bps; Selectable fixed rate or autobaud Line speeds (synchronous): 33.6K, 31.2K, 28.8K, 26.4K, 24K, 21.6K, 19.2K, 16.8K, 14.4K, 12K, 9600, 7200, 4800, 2400, 1200 and 300 bps (300 bps async. only); Z34-SE—33.6K to 300 bps, Z32t-SE—19.2K to 300 bps, Z32b-SE—14.4K to 300 bps Autorate (fallback/forward): 33.6K, 31.2K, 28.8K, 26.4K, 24K, 21.6K, 19.2K, 16.8K, 14.4K, 12K, 9600, 7200, and 4800 bps ;(Z32t-SE—19.2K to 4800 bps, Z32b-SE—14.4K to 4800 bps) Operation 2-wire full-duplex dial-up and 2-wire leased line with dial backup and auto-restoral Data Format Asynchronous: 8, 9, 10, or 11 bits; Synchronous: serial, binary; note 8, 9, 11 bit data modes do not operate with MNP or V.42 error control DTE Interface EIA-232D, ITU-T V.24 Transmit Level Dial-up: -10 dBm; Leased line: -6 dBm to -15 dBm selectable Receiver Sensitivity Dial-up: -10 to -43 dBm; Leased line: -6 dBm to -43 dBm Clock Timing Internal, external, or slave LED Display TXD, RXD, CTS, DSR, DTR, CXR, EC, AA, SYN, SPD, FAX Front-Panel Keys DATA, TEST (3-second hold of DATA key dials stored number) Switches 10 DIP switch options, power on/off, speaker and volume control Remote Control Local control of remote Zypcom modems via secondary channel Security Commands for 10-user password, callback and memory security Diagnostics Self-Test (ST), ALB, ALB-ST, DLB, RDLB, RDLB-ST, V.54 Dimensions Height: 1.5"; Width: 4.5"; Length: 7.5"; Weight: 1.5 lbs. Power Requirements 110VAC—95 to 127VAC, 60Hz; 220VAC—190 to 250VAC, 50Hz Temperature Operating: 0° to 50° C (32° to 122° F) ambient; Storage: -20° to 70° C (-4° to 158° F); Humidity: 5% to 95% non-condensing Compliance FCC Part 68, Part 15—Class B, UL/CSA/DOC/TUV/IEC, REN 0.8B Auto-Dialer Protocols Hayes AT, dial_on_DTR, V.25bis async. and V.25bis sync. Dialer Type & Data Type: Tone or pulse Data: Async.—AT & V.25bis 10 bit; Sync.—V.25bis HDLC or BSC Dialing Directory 4 numbers, 68 characters each Error Control and Data Compression Protocol V.42bis, V.42 and MNP Classes 25 Operation Automatic, forced on or off Flow Control Software: Uni/Bi-directional Xon/Xoff; Hardware: RTS/CTS Facsimile Compatibility ITU-T Group III fax machines and fax modems ITU-T V.17, V.29, V.27ter, V.21 Channel 2, T.30, T.4 EIA-578/592 Class 1 and Class 2 compatibility for fax software Operating Speeds Send/Receive: 14,400 bps to 2400 bps Ordering Information for Zypcom Z34-SE, Z32t-SE, Z32b-SE Each SE-Series modem includes a telephone cable—P/N 15047-004, User's Guide and 110VAC power supply. For 220VAC power supply, indicate after model number when ordering (example: Z34-SE, 220V).
Models Description Zypcom Z34-SE, Z32t-SE, Z32b-SE Z34-SE External 33.6K modem Z32t-SE External 19.2K modem Z32b-SE External 14.4K modem Options SuperFax Windows data and fax software 94200-095 48VDC power supply 94200-100 24VDC power supply 94200-101 12VDC power supply 91009-202 2-wire leased line cable (RJ11 to RJ11) Z34-SX, Z34-SXL and Z34-SE modem manual (pdf 898 kb) |
Specials E-mail us Bookmark this site Important Notices
|