Verilink - Call 727-398-5252 for Verlink and all of your WAN / LAN needs

[Home][Adtran][Cisco][Eastern Research][GDC][Kentrox][Micom][Motorola][Multi-Tech][Nortel][RAD][Verlink][Visual Networks]

Verilink - home Specials on Verilink and other WAN / LAN data communications equipment Search for Verilink or other WAN / LAN data communications equipment Request a quote on Verilink and other WAN / LAN data communications equipment

Verilink / Transport / TxPort
Verilink


T Lite Single-Port T1 CSU
T Lite is a Single-port, frame-transparent T1 CSU. It can detect and activate network initiation loopbacks, monitor bipolar violations, and maintain pulse density of the transmitted signal. The unit is transparent to framed (D4 or ESF) or unggramed T1 signals and can operate in either AMI or B8ZS line coding mode.
bulletT Lite T1 RJ-48C CSU.
bulletDDS Lite DSU/CSU

2000 Single-Port T1 ESF CSU
Single-Port T1 Extended Super Frame (ESF) CSU Applications: Used in applications requiring FT1/T1 circuit termination with drop-and-insert capabilities via RJ-48C port. SNMP/Telnet management through the 8100A Site Controller.
-48 VDC (110 VAC requires 30-00087 power supply).

bullet2000 T1 RJ-48C ESF CSU - SNMP standalone.

2100 Single-Port T1 CSU -48 VDC
The 2100 standalone T1 CSU with hardened lightening protection.
-48 VDC (110 VAC requires 30-00087 power supply).

bullet2100 T1 RJ-48C CSU - standalone.

301 Single -Port E1 DSU/CSU
Single Port E1 DSU / CSU Applications. Used in applications requiring unmanaged E1 circuit termination. The 301 is available as a standalone or with rack mount ears (optional part 9-300-002-1).

bullet301 E1/FE1 DSU/CSU with V.35 DTE port and 75 ohm coax network port - standalone.
bullet301 E1/FE1 DSU/CSU with V.35 DTE port and 120 ohm RJ-48C network port - standalone.
bullet301 E1/FE1 DSU/CSU with V.35 DTE port and 120 ohm DB-15 network port - standalone.
bullet301 E1/FE1 DSU/CSU with V.35 DTE port and 120 ohm twin-ax network port - standalone.
bullet301 E1/FE1 DSU/CSU with EIA 530 DTE port and 75 ohm coax network port - standalone.
bullet301 E1/FE1 DSU/CSU with EIA 530 DTE port and 120 ohm RJ-48C network port - standalone.
bullet301 E1/FE1 DSU/CSU with EIA 530 DTE port and 120 ohm DB-15 network port - standalone.
bullet301 E1/FE1 DSU/CSU with EIA 530 DTE port and 120 ohm twin-ax network port - standalone.
bullet301 E1/FE1 DSU/CSU with X.21 DTE port and 75 ohm coax network port - standalone.
bullet301 E1/FE1 DSU/CSU with X.21 DTE port and 120 ohm RJ-48C network port - standalone.
bullet301 E1/FE1 DSU/CSU with X.21 DTE port and 120 ohm DB-15 network port - standalone.
bullet301 E1/FE1 DSU/CSU with X.21 DTE port and 120 ohm twin-ax network port - standalone.
bullet301 E1/FE1 DSU/CSU with V.35 DTE port and 75 ohm coax network port - rack mount.
bullet301 E1/FE1 DSU/CSU with EIA 530 DTE port and 75 ohm coax network port - rack mount.

8100A Site Controller
Central site SNMP and Telnet network management module of up to 100 logical devices via one IP address.

bullet8100A site controller base unit.
bullet8100A site controller base unit 10BaseT.
bullet8100A site controller base unit with Token Ring.
bullet8100A site controller base unit with AUI Ethernet.
bullet8100A site controller base unit with integral 14.4 kbps modem.
bullet8100A site controller base unit with integral 14.4 kbps modem and 10BaseT.
bullet8100A site controller base unit with integral 14.4 kbps modem and Token Ring.

Automatic Protection Switch (APS)
Verilink APS units constantly monitor the status and quality of both the active access line and the standby access line receive signals and provide the necessary switching to provide a single DS1 output.

     APS Chassis

bulletAPS chassis supports up to fourteen D4/ESF APS cards. Supplied with Alarm/Power card. Requires and external -48 VDC power source (2.5 Amps max). Includes 1250 Alarm/Power distribution card.

     APS Application Modules

bullet1557 APS card switches on selectable error events and is T1.403, TR54016, and AT&T 54017 compatible. Configuration guide included. Manuals shipped upon request only.
bulletAPS dual LIU card converts two DSX level signals to line levels with protection. Designed as a companion product to the 1557 APS to allow the 1557 to drive two facility lines.
bullet1250 Alarm/Power distribution card. Interfaces two -48 VDC external sources to the APS Chassis. This card is furnished standard with the APS chassis. It provides a Chassis Alarm indication whenever any of the installed cards is in an alarm state and also provides switches for Chassis Addresses.
bullet1558A Standalone APS unit provides Automatic Protection Switching and T1 performance monitoring for a single APS application. Switching from the active line to the standby line is determined by user programmable alarm thresholds. The DTE port may be configured for D4 or ESF Framing and AMI or B8ZS coding. Dual ESF CSU functionality. -20 to -56VDC. Ships with AC/DC wall transformer, 19" rack mount hardware, PC Local Access Software, Pc to 1558 data cable, and three 10 ft. Rj48 modular T1 cables.
bullet1558D Standalone APS unit provides Automatic Protection Switching and T1 performance monitoring for a single APS application. Switching from the active line to the standby line is determined by user programmable alarm thresholds. Integral ESF DSU/CSU. Ships with AC/DC wall transformer, 19" rack mount hardware, PC Local Access Software, PC to 1558 data cable, and three 10 ft RJ48 modular T1 cables.

     APS Site Manager

bullet1559 APS Site Manager configured for 110 VAC/ -48VDC operation, no internal modems (external modems may not be used).
bullet1559 APS Site Manager configured for 110 VAC/ -48 VDC operation with two internal modems.
bullet1559 APS Site Manager configured for -48 VDC operation, no internal modems (external modems may not be used).
bullet1559 APS Site Manager configured for -48 VDC operation with two internal modems.

     APS Accessories

bullet23" Rack Mount Hardware. Ordered as an option to the 1558
bulletPC DOS Local Access Software (3.5" Disk). Allows the user to access unit performance, status, and configuration information. Also allows the user to perform local loop testing.
bullet10' Assy. (supv) 8 pin to 6 pin modular, straight through PC cable with DB9 to RJ48 adapter

1060 Series Broadcast Cards
Verilink Broadcast cards are used to expand a single T1 into 12  (1061) or 14 (1060) T1 outputs - cases where bridging may not be possible or practical

bulletVerilink 1060 Broadcast card used to expand a single T1 input to 14 T1 outputs. The inputs are redundant. They switch from the primary (A) to the secondary port (B) on receipt of an alarm indication signal (AIS) or on a loss of signal (LOS) The 1060 card is designed to be installed in a single unit housing module for stand a lone desktop or for wall mounting.
bulletVerilink 1061 Broadcast Card is used to expand a single T1 input to 12 T1 outputs. The inputs are redundant and offer diagnostic capabilities for each T1 output. Configuration via VT100 interface and configuration switches. Managed via the 8100A site controller.

Productivity Series
Verilink Productivity Series DDS and T1/FT1 DSU/CSUs offer low-cost access to digital facilities. DIP switch configuration with LED status indicators.

bulletProductivity Series 300 T1/FT1 DSU/CSU. Single V.35 (M34) DTE interface. Rack mount ears included.
bulletProductivity Series 400 multirate DDS DSU/CSU. Includes both V.35 (M34) and RS-232 (DB25) DTE interfaces.

Office Connect
Verilink OfficeConnect® DSU/CSUs are designed to fit the 3Com OfficeConnect® Stack of networking equipment.

bulletT1 DSU/CSU with single V.35 port, 110V, SNMP/TELNET, SLIP, RS232 DBU option.
bulletT1 DSU/CSU with single V.35 port, SNMP/TELNET, 110V, T1/DTE, SLIP, RS232 DBU option.
bulletT1 DSU/CSU with single V.35 port, SNMP/TELNET , 110V, Ethernet, RS232 DBU option.
bulletT1 DSU/CSU with single V.35 port, 110V, SNMP/TELNET, T1/DTE, Ethernet, RS232 DBU option.
bulletT1 DSU/CSU with single V.35 port, SNMP/TELNET, 110V, Token Ring, RS232 DBU option.
bulletT1 DSU/CSU with single V.35 port, 110V, SNMP/TELNET, T1/DTE, Token Ring, RS232 DBU option.
bulletDDS DSU/CSU supports DDS rates from 56kbps to 64kbps clear channel for synchronous applications. Embedded SNMP/TELNET Management. RS-232 (DDS-I and DDS-II)
bulletDDS DSU/CSU supports DDS rates from 56kbps to 64kbps clear channel for synchronous applications. Embedded SNMP/TELNET Management. RS-232 and Ethernet (DDS-I and DDS-II)
 

                    Immediate price quote - Call 727-398-5252

Specials   E-mail us   Bookmark this site   More Verilink   Important Notices

Use Visa to purchase Data Communications Equipment    Use MasterCard to purchase Data Communications Equipment
E-mail: Webmaster about the Verilink portion of this site.Verilink logo
Last modified: February 04, 2007