Verilink
1051 Multiline Chassis

Model 1051 universal chassis with DB-25 or V.35 female DTE connectors. Holds up to twelve 2000, 2100, 2010, 3001, 4001 or 4051 modules in any combination. Power shelves provide distributed AC power for the 1051 and must be ordered separately or as a 1051 shelf bundle. If no power shelf is used, the customer must supply -48 VDC.

Verilink 1051 Shelf Bundles

bullet1051 Chassis with V.35 DTE connectors coupled with a 1040 power rack and one power supply module.
bullet1051 Chassis with V.35 DTE connectors coupled with a 1041 power rack and two power supply modules (redundant power).
bullet1051 Chassis with DB-25 DTE connectors coupled with a 1040 power rack and one power supply module.
bullet1051 Chassis with DB-25 DTE connectors coupled with a 1041 power rack and two power supply modules (redundant power).
bullet1051 Chassis with V.35 DTE connectors coupled with a 1041 power rack and one power supply module (capable of redundant power by adding a second power module 9-1000-48V-2).
bullet1051 Chassis with DB-25 DTE connectors coupled with a 1041 power rack and one power supply module (capable of redundant power by adding a second power module 9-1000-48V-2).

Verilink 1051 Individual Items

bullet1051-2 Chassis with DB-25 DTE connectors.
bullet1051-3 Chassis with V.35 DTE connectors.
bulletThe 1041 power supply shelf converts 115 VAC to -48 VDC for the 1051 chassis. This shelf features individual barrier terminal strip for up to eight individual units with independent fusing. An alarm relay provides local alarm for any one of the individual fused outputs as well as either of the power modules. Fits in 19" equipment rack - (for 23" rack use 9-2000-002-2 conversion kit). Uses 9-1000-48V-2 power modules (not included).
bulletPower module for 1041 or 1042 power shelf.
bullet1040 Dual Power Shelf for 1051 shelf. Converts 115 VAC to -48 VDC for the 1051 chassis. Uses one or two 9-1000-48V-1 power modules (not included).
bullet-48 VDC, 2A power supply for mounting in 1040 power shelf.
bulletDual Power Shelf bundled with one 9-1000-48V-1 power supply module to power one 1051 chassis. Fits in 19" equipment rack (for 23" racks use 9-2000-002-2 conversion kit).
bulletDual Power Shelf bundled with two 9-1000-48V-1 power supplies to power two 1051 chassis. Fits in 19" equipment rack (for 23" racks use 9-2000-002-2 conversion kit).

Verilink 1051 Controller Module (8100A)

bullet8100A base module.
bullet8100A base module with 10BaseT.
bullet8100A base module with Token Ring.
bullet8100A base module with AUI Ethernet.
bullet8100A base module with integral 14.4 kbps modem.
bullet8100A base module with integral 14.4 kbps modem and 10BaseT.
bullet8100A base module with integral 14.4 kbps modem and Token Ring.

Verilink 1051 Application Modules

    2000 (Single-port T1 ESF CSU Module)

bullet2000 T1 ESF CSU with hardened lightening protection. SNMP/Telnet through 8100A.

     2100 (Single-port T1 CSU Module)

bullet2100 T1 CSU with hardened lightening protection.

     PRISM 3001 (single-port SNMP T1/DSU/CSU Modules)

bulletPRISM 3001 T1 DSU/CSU with V.35 and RS-423 station clock. SNMP/Telnet through 8100A.
bulletPRISM 3001 T1 DSU/CSU with V.35, DSX-1 and RS-423 station clock. SNMP/Telnet through 8100A.
bulletPRISM 3001 T1 DSU/CSU with EIA530 and RS-423 station clock. SNMP/Telnet through 8100A.
bulletPRISM 3001 T1 DSU/CSU with EIA 530, DSX-1 and RS-423 station clock. SNMP/Telnet through 8100A.

     PRISM 3021 (Single-port E1 DSU/CSU Modules)

bulletPRISM 3021 E1/FE1 DSU/CSU with a single V.35 data port and 75 ohm coax network port.
bulletPRISM 3021 E1/FE1 DSU/CSU with a single V.35 data port, 120 ohm RJ-48C DSX-1 port and 75 ohm coax network port.
bulletPRISM 3021 E1/FE1 DSU/CSU with a single V.35 data port, 120 ohm twin-ax DSX-1 port and 75 ohm coax network port.
bulletPRISM 3021 E1/FE1 DSU/CSU with a single V.35 data port, 120 ohm DB-15 DSX-1 port and 75 ohm coax network port.
bulletPRISM 3021 E1/FE1 DSU/CSU with a single V.35 data port, 75 ohm Coax DSX-1 port and 75 ohm coax network port.
bulletPRISM 3021 E1/FE1 DSU/CSU with a single V.35 data port and 120 ohm RJ-48C network port.
bulletPRISM 3021 E1/FE1 DSU/CSU with a single V.35 data port, 120 ohm RJ-48C DSX-1 port and 120 ohm RJ-48C network port.
bulletPRISM 3021 E1/FE1 DSU/CSU with a single V.35 data port, 120 ohm twin-ax DSX-1 port and 120 ohm RJ-48C network port.
bulletPRISM 3021 E1/FE1 DSU/CSU with a single V.35 data port, 120 ohm DB-15 DSX-1 port and 120 ohm RJ-48C network port.
bulletPRISM 3021 E1/FE1 DSU/CSU with a single V.35 data port, 75 ohm Coax DSX-1 port and 120 ohm RJ-48C network port.
bulletPRISM 3021 E1/FE1 DSU/CSU with a single V.35 data port and 120 ohm DB-15 network port.
bulletPRISM 3021 E1/FE1 DSU/CSU with a single V.35 data port, 120 ohm RJ-48C DSX-1 port and 120 ohm DB-15 network port.
bulletPRISM 3021 E1/FE1 DSU/CSU with a single V.35 data port, 120 ohm twin-ax DSX-1 port and 120 ohm DB-15 network port.
bulletPRISM 3021 E1/FE1 DSU/CSU with a single V.35 data port, 120 ohm DB-15 DSX-1 port and 120 ohm DB-15 network port.
bulletPRISM 3021 E1/FE1 DSU/CSU with a single V.35 data port, 75 ohm coax DSX-1 port and 120 ohm DB-15 network port.
bulletPRISM 3021 E1/FE1 DSU/CSU with a single V.35 data port and 120 ohm twin-ax network port.
bulletPRISM 3021 E1/FE1 DSU/CSU with a single V.35 data port, 120 ohm RJ-48C DSX-1 port and 120 ohm twin-ax network port.
bulletPRISM 3021 E1/FE1 DSU/CSU with a single V.35 data port, 120 ohm twin-Ax DSX-1 port and 120 ohm twin-ax network port.
bulletPRISM 3021 E1/FE1 DSU/CSU with a single V.35 data port, 120 ohm DB-15 DSX-1 port and 120 ohm twin-ax network port.
bulletPRISM 3021 E1/FE1 DSU/CSU with a single V.35 data port, 75 ohm coax DSX-1 port and 120 ohm twin-ax network port.

     PRISM 4001 (Single-port DDS DSU)

bulletPRISM 4001 DDS-1 DSU/CSU with user-selectable RS-232 or V.35 DTE interface. SNMP/Telnet through 8100A.
bulletPRISM 4001 DDS-1 DSU/CSU with user-selectable RS-232 or V.35 DTE interface and 33.6 kbps dial-backup option. SNMP/Telnet through 8100A.

     PRISM 4051 (Single-port DDS DSU)

bulletPRISM 4051 DDS I/ II DSU/CSU with V.35 DTE interface. SNMP/Telnet through 8100A.
 

                    Immediate price quote - Call 727-398-5252

Specials   E-mail us   Bookmark this site   More Verilink   Important Notices

Use Visa to purchase Data Communications Equipment    Use MasterCard to purchase Data Communications Equipment
E-mail: Webmaster about the Verilink portion of this site.Verilink logo
Last modified: February 04, 2007