FSU 5622 ESP

VOICE/DATA FRAME RELAY ACCESS/DDS MUX
Part# 1200175L1

The ADTRAN FSU 5622 ESP (Part# 1200175L1 ) is a standalone frame relay access device (FRAD) that provides a cost-effective means of transporting voice and multi-protocol data over frame relay and DDS networks. The ADTRAN FSU 5622 ESP provides an easy-to-use interface for customers migrating existing services or developing new applications for operation over frame relay networks.

The ADTRAN FSU 5622 ESP (Part# 1200175L1 ) provides economical means to provide high-quality voice and fax capabilities to remote locations without expensive toll charges. In frame relay networks the ADTRAN FSU 5622 ESP allows voice and data to share the same Permanent Virtual Circuit (PVC) eliminating unnecessary PVC charges associated with other vendor's voice and data frame relay products. Two voice ports are provided when configured with the appropiate ESP option card. Options include: ESP Dual FXS, ESP Dual FXO, and ESP Dual E&M.

The ADTRAN FSU 5622 ESP (Part# 1200175L1 ) provides two independent DTE interfaces for connecting non-frame relay devices to the frame relay network. The DTE ports support synchronous data rates from 2.4 to 64 kbps and asynchronous from 2.4 to 38.4 kbps. Both EIA-232 and V.35 physical interfaces are available for connection to the customer's DTE equipment. The FSU 5622 ESP's concentrator feature allows the connection of two frame relay devices to a single frame relay network interface. The FSU 5622 ESP supports SNA, SDLC, Bisync, SLIP, IP, PPP (both synchronous and asynchronous), frame relay, BOP, and asynchronous protocols. The DTE ports can be configured independently, providing support for multi-protocol applications.

The Dial BackUp (DBU) Dial Backup feature of the ADTRAN FSU 5622 ESP (Part# 1200175L1 ) allows automatic or manual switched backup in the event of a dedicated line failure or a frame relay connector failure. The addition of DBU is accomplished through a family of plug-in ESP DBU cards. There are three versions of ESP DBU cards available for the FSU 5622 ESP: 4-wire Switched 56, V.34 modem,and 1B+D ISDN. Upon recognition of a failure(s), the unit connects to the remote end using the switched network. The user can choose whether the unit automatically or manually reverts to the dedicated circuit when it is restored. Optional weekend and time of day DBU dial backup lockout options are provided.

Embedded SNMP and telnet are available through a SLIP/PPP(Async) port when operating in a DDS environment and in-band for frame relay networks. SNMP is provided with support for RFC 1315 and MIB II. Through the Management Information Base (MIB)-II standard and an ADTRAN-supplied enterprise MIB, the FSU 5622 ESP can be configured, monitored, and diagnosed using standard SNMP network management programs such as HP OpenView®, NetView®, and SunNet Manager®.

Complete control, configuration, and diagnosis are available through a 16-position keypad and a two-line by 16-character LCD display. A VT 100 terminal configuration and control mode is also available through the control port. Flash download capability is implemented for installation of new features and enhancements.

Features of the ADTRAN FSU 5622 ESP (Part# 1200175L1 )

bulletDual Voice Port support; options include Dual FXS, Dual FXO, and Dual E&M
bulletTwo Independent DTE Data Ports
bulletIntegral 56/64 DDS DSU/CSU
bulletSNMP/Telnet Management
bulletRFC 1490 encapsulation for IP & LLC2
bulletSDLC local port spoofing
bulletAutomatic or manual dial backup
bulletDial backup available with ESP DBU cards; options include 4-wire Switched 56, V.34, and ISDN
bulletTime of day and weekend dial backup lockout options Dual Voice Support
bulletFrame relay management using ANSI, ITU, or LMI formats
bulletEasy to use VT 100 interface for configuration
bulletStandard 5 year warranty

FSU 5622 ESP APPLICATION EXAMPLE

FSU 5622 ESP REAR PANEL

Product Specifications

OPERATING MODES

bulletDedicated point-to-point DDS
bulletFrame Relay utilizing DDS

NETWORK DATA RATES

bulletDedicated mode service rates: 56, and 64 kbps
bulletSwitched mode service rate: 56 kbps
bulletDial Backup: Switched 56 (56 kbps) V.34 (2.4 - 33.6 kbps) ISDN (56 or 64 kbps)

DTE RATES PROVIDED

bulletSynchronous rates: 2.4 to 64 kbps
bulletAsynchronous rates: 2.4 to 38.4 kbps

VOICE SUPPORT

Compression

bulletVoice Compression G.723.1 (MP-MLQ)
bullet4.7 - 16k Compressed Voice
bulletMOS - 3.9

FAX Support

bulletGroup III
bulletGroup III 0.3 - 9.6 kps

Dual FXS

bulletLoop Start 2-wire voice
bulletLine Current and Ring Voltage Supplied
bulletMessage Waiting Light Support
bulletR.E.N. - 3
bulletTIA 464A DTMF decode and regeneration
bulletG.265 Echo Cancellation

Dual FXO

bulletLoop Start 2-wire
bulletvoice Message Waiting Detection

Dual E&M

bullet2- or 4-wire
bulletType I & II E&M signaling

PROTOCOL SUPPORT

Concentrator

bulletFrame Relay

IBM Support

bulletSNA/SDLC with local spoofing
bulletDLC/HDLC transparent
bulletSDLC-LLC2 translation
bulletSupports up to 20 SDLC PUs on each DTE port

LAN Protocol

bulletSLIP
bulletIP-PPP asynchronous or synchronous

Transparent

bulletAsynchronous transparent
bulletBOP transparent

Protocol Encapsulation

bulletIP (SLIP and PPP) and LLC2 protocols are encapsulated using RFC 1490 formats
bulletAll other protocols use proprietary formats and require ADTRAN devices at each UNI

DTE DATA INTERFACES

bulletEIA-232 electrical and physical interfaces
bulletV.35 electrical, physical with adapter cable

CONTROL PORT INTERFACE

bulletSNMP & Telnet
bulletElectrical: EIA-232
bulletPhysical: RJ-48S (female DB25 adapter provided)
bulletData Rates: Async 2.4 to 38.4 kbps

SNMP

bulletInternal SNMP agent
bulletMIB II RFC 1213
bulletFrame Relay DTE MIB RFC 1315
bulletADTRAN enterprise MIB
bulletTelnet Access

DATA FLOW CONTROL

bulletSynchronous: Clock Slowing
bulletAsynchronous: CTS or XON/XOFF

DIAGNOSTICS

bulletCSU and DSU loopbacks
bulletIP Ping Mode
bulletAll port loopback mode

LINE REQUIREMENTS

bulletLoop transmission parameters as defined in: AT&T PUB 62310: Dedicated DDS AT&T PUB 4146B: Switched 56 Sprint TS 0046: Switched 56

RECEIVER SENSITIVITY

bullet-45 dB at all rates

AGENCY APPROVALS

bulletFCC part 15, Class A and Part 68
bulletIndustry Canada CS03
bulletUL and CUL

ENVIRONMENT

bulletOperating: 0° to 50° C (32° to 122° F)
bulletStorage: -20° to 70° C (-4° to 158° F)
bulletRelative Humidity: Up to 95%, non-condensing

PHYSICAL

bulletDimensions: 10.4"D x 8.0"W x 2.4"H
bulletWeight: 4.5 lbs.
bulletPower: 115 VAC, 60 HZ, 10 W

PRODUCT INCLUDES

bulletTwo 8-pin to 8-pin modular cables
bulletModular to Female DB-25 adapter
bulletUser manual

HP OpenView is a registered trademark Hewlett Packard Company
NetView is a registered trademark of IBM Corporation
SunNet Manager is a registered trademark of Sun Microsystems, Inc.
 
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.

Ordering Information

bulletFSU 5622 ESP - 1200175L1
bulletESP Dual FXO Card - 1200187L1
bulletESP Dual FXS Card - 1200188L1
bulletESP 4-wire Switched 56 DBU Card - 1204001L1
bulletESP V.34 DBU Card - 1204002L1
bulletESP ISDN DBU Card - 1204004L1
bulletV.35 Adapter Cable Male 6ft. - 1200193L1
bulletV.35 Adapter Cable Female 6ft. - 1200194L1

Download this brochure in pdf format.

                    Immediate price quote - Call 727-398-5252

Specials   E-mail us   Bookmark this site   More Adtran    Important Notices

Use Visa to purchase Data Communications Equipment    Use MasterCard to purchase ADTRAN Equipment
ADTRAN and the ADTRAN logo are registered trademarks of ADTRAN, Inc.Adtran Logo
E-mail: Webmaster about the Adtran portion of this site.
Last modified: November 07, 2007